Mechanisms of structural failure
Contents |
[edit] Introduction
Structural failure refers to defects in which a load bearing component of the building is unable to support and transfer loads to another element. Structural failure develops due to breakdown in the performance of the materials in a structural component may be caused by:
- Erroneous construction: Failure of the engineer to supervise all the construction activities at the site resulting in faults to construction elements which later develop into failure; issues like use of salty sand in making concrete, use of poor grade steel not as specified, improper tightening of torque nuts, bad welds and so on.
- Improper design: Failure of the engineer to account for all the loads the structure is to carry, application of erroneous design theories, use of inaccurate data, not taking account of the impacts of repetitive or impulsive stresses, improper use of materials, misunderstanding of properties and so on.
- Foundation failures: Failure of the ground on which the foundation rests to carry load, causing displacements, altering the stress distribution to the whole structure and so on.
- Overloading: Excess loads that are applied beyond that which had been anticipated, these loads might be due to vibrating earthquake, heavy snow loads, hurricanes, storage, change of use and so on.
- Innovation: New types of structures subject to unexpected failures.
[edit] Compressive and tensile failure
Compressive failure can be sudden and catastrophic, apparent by cross breaks caused by the excessive longitudinal compression or bending. Tensile failure can be detected by stretching in the sizes of the member. These elongations come along with cracks that orient perpendicular to the direction of the tensile forces.
[edit] Bending failure
Bending is the bowing deformation of a beam or other member under load. Bending stress can be slow or sudden depending on the nature of the force applied, whether compressive or tensile forces.
[edit] Shear failure
Shear failure is principally an internal splitting force caused by two forces acting in opposite directions at a distance to one another along the cross section of a structural member. Shear cracks are diagonal, for example, appearing in the web of a beam.
[edit] Buckling failure
Buckling is a creasing failure by crumpling of a longitudinal structural member loaded eccentrically with a compressive force. It occurs to long and slender members subject to axial compressive stress. Buckling load is a compressive load at which a column or strut begins to buckle. Steel columns are more prone to buckling than concrete columns because they are more slender. Also slender beams and floor joists fail due to compressive stresses resulting from the bending.
Buckling Vs. Bending
Buckling | Bending |
Occurs when the load reaches a certain critical value known as Critical load | Occurs under all magnitudes of loads applied to a structural component. |
Buckling takes place abruptly. | May be sudden or gradual, it gives warning signs of failure of the structural component before complete collapse. |
Buckling under load members become unstable, but will generally not fracture | Bending under load member deflects, it may start to develop some cracks. |
Instability caused by buckling in one member can lead to excessive stresses in other members causing progressive collapse of the whole structure. | The defects developed due to bending stress cause less effect to progressive failure of the whole structure. |
Buckling is due to axial stresses applied along the longitudinal axis of the member. | Bending is a combination of tensile and compressive stresses. |
For a member to withstand loads against buckling failure it should be designed to reduce its slenderness by increasing its cross-sectional dimension.
Bracing a member at its intermediate points along its length or height
For economical reasons consider bracing a member as cheaper and easier than increasing its cross sectional dimensions this is uneconomical.
[edit] Conclusion
Compressive, tensile, bending and buckling are the basic types of structural failure for construction elements. These are caused due to faults in design and construction. To mitigate these failures the structural engineer has to properly study properties of the structural materials, loads to be applied and the use of the structure to propose an appropriate material, adequate cross section and a proper structural system.
[edit] Related articles on Designing Buildings
- Biaxial bending.
- Building failure.
- Consolidation.
- Cracking and building movement.
- Defects.
- Defects in brickwork.
- Defects in dot and dab.
- Defects in stonework.
- Failure of cast iron beams.
- Failure to mention asbestos.
- Flat roof defects.
- Flooring defects.
- Force.
- Ground heave.
- Housing defects.
- In Plain Sight: reducing the risk of infrastructure failure.
- Latent defects.
- Patent defects.
- Roofing defects.
- Shear force.
- Smarter systems predicting failure.
- Structural failures.
- Strut.
- The future infrastructure of Scotland.
- Ties.
- Wall tie failure.
Featured articles and news
Licensing construction; looking back to look forward
Voluntary to required contractors (licensing) schemes.
A contractor discusses the Building Safety Act
A brief to the point look at changes that have occurred.
CIOB Construction Manager of the Year award
Shortlist set to go head-to-head for prestigious industry title.
How orchards can influence planning and development.
HSE simplified advice for installers of stone worktops
After company fined for repeatedly failing to protect workers.
Co-located with 10th year of UK Construction Week.
Time for knapping, no time for napping
Decorative split stone square patterns in facades.
A practical guide to the use of flint in design and architecture.
Designing for neurodiversity: driving change for the better
Accessible inclusive design translated into reality.
RIBA detailed response to Grenfell Inquiry Phase 2 report
Briefing notes following its initial 4 September response.
Approved Document B: Fire Safety from March
Current and future changes with historical documentation.
A New Year, a new look for BSRIA
As phase 1 of the BSRIA Living Laboratory is completed.
A must-attend event for the architecture industry.
Caroline Gumble to step down as CIOB CEO in 2025
After transformative tenure take on a leadership role within the engineering sector.
RIDDOR and the provisional statistics for 2023 / 2024
Work related deaths; over 50 percent from construction and 50 percent recorded as fall from height.